RT/F3 E1/E2/E3 Type Axle Counter Cable
Application
The cables are designed for transmission of signals up to 90 kHz in axle counter train detection systems.
Standard
- RT/E/PS/00031
Cable Construction
- Conductors: Tinned copper, 0.9/1.4 mm nominal diameter.
- Insulation: Solid polyethylene.
- Cabling Element: Two insulated conductors are twisted together to form a pair.
- Stranding: Pairs are helically stranded in concentric layers.
- Filling: Cable core interstices are filled with a low-permitivity compound. Unfi lled cables option can be offered upon request.
- Core Wrapping: Plastic tape(s) with overlapping.
- Moisture Barrier: One laminated sheath made of aluminium tape coated with PE Copolymer on at least one side is applied with longitudinally overlap.
- Inner Sheath: Polyethylene or LSZH fi re retardant compound.
- Electrostatic Shield: One layer of helically applied copper wires.
- Electromagnetic Shield: Two helically applied steel tapes.
- Outer Sheath: Polyethylene or LSZH fi re retardant compound. Ruggedised PE sheath compound can be offered upon request.
Type Codes
- F1 class: Non LSZH cables.
- F5 class: Unfi lled cables
- D type: Unarmoured types
- R type: Ruggedised PE sheath
- S type: Steel tape armoured types
- B type: Brass tape armoured types
- E1, E2 & E3 types: 3 different induction protection levels available.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm | 0.9 | 1.4 |
Nominal Conductor Cross Section | mm | 0.63 | 1.5 |
Maximum Conductor Resistance | Ω/km | 30.0 | 12.5 |
Minimum Insulation Resistance @500 V DC (1min) | MΩ.km | 5000 | 5000 |
Nominal Conductor Capacitance @800Hz/1000Hz (AC) | nF/km | 42+3 | 47+3 |
Dielectric Strength, conductor to screen (DC voltage 2mins) | V | 3000 | 3000 |
Maximum Average Attenuation | |||
@1.0KHz | dB/km | 0.73 | 0.45 |
@2.4KHz | dB/km | 1.10 | 0.62 |
@40KHz | dB/km | 2.88 | 1.77 |
@90KHz | dB/km | 3.70 | 2.41 |
@1.024MHz | dB/km | 11.2 | 7.45 |
Minimum Average Near-end Crosstalk | |||
@1.0KHz | dB/km | 60 | 60 |
@2.4KHz | dB/km | 60 | 60 |
@40KHz | dB/km | 50 | 50 |
@90KHz | dB/km | 50 | 50 |
@1.024MHz | dB/km | 35 | 35 |
Maximum Reduction Factor @100V/km,50Hz | |||
EMI RF 1 (modest level) | 0.65 | 0.65 | |
EMI RF 2 (medium level) | 0.45 | 0.45 | |
EMI RF 3 (high level) | 0.20 | 0.20 |
Mechanical and Thermal Properties
- Minimum Bending Radius: 7.5×OD (unarmoured); 10×OD (armoured)
- Temperature Range: -30℃ to +60℃ (during operation); -10℃ to +60℃ (during installation)
Dimensions and Weight
Cable Code | Number of Pairs |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
|
---|---|---|---|---|---|
Inner | Outer | ||||
0.9mm Conductor , 1.8mm Insulated Wire | |||||
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-2P0.9 | 2 | 2.2 | 2.4 | 23.4 | 1300 |
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-10P0.9 | 10 | 2.2 | 2.4 | 31.8 | 1650 |
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-12P0.9 | 12 | 2.2 | 2.4 | 35.0 | 1760 |
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-19P0.9 | 19 | 2.2 | 2.4 | 41.4 | 2275 |
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-24P0.9 | 24 | 2.2 | 2.4 | 44.0 | 2450 |
1.4mm Conductor, 2.7mm Insulated Wire | |||||
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-2P1.4 | 2 | 2.2 | 2.4 | 33.6 | 1480 |
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-10P1.4 | 10 | 2.2 | 2.4 | 40.2 | 2200 |
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-12P1.4 | 12 | 2.2 | 2.4 | 42.2 | 2325 |
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-19P1.4 | 19 | 2.2 | 2.4 | 47.5 | 2975 |
RS/RT/F3-S/E3-2Y(F)(L)2YDB2Y-24P1.4 | 24 | 2.2 | 2.4 | 52.5 | 3150 |